User's Manual

Table Of Contents
649 mod_los : on err
650 rfi_los : off err
651 rfi_fer : off ok
652 idu_temp : on ok
653 odu_temp : on err
654 odu_RxL : on err
655 odu_comm : on err
656 odu_alarm : on ok
657 license : on ok
660 idu_hwerr : on ok
661 idu_swerr : on ok
600 g703_p1_link : off ok - in HSI 2xE1 modules there is no link by first channel
601 g703_p1_ais : off ok - in HSI 2xE1 module there is AIS signal by first channel
602 g703_p2_link : off ok - for 2nd channel, setting “set ala add/rem g703 ch2”
603 g703_p2_ais : off ok
632 lana1_link : off err - there is no link by Gbit eth, setting “set rep add/rem c channel”
636 lanb1_link : off ok - similarly, setting “set ala add/rem lanb1”
640 hsi_los : off err - by HSI e3 modules there is no frame sync “set ala add hsi”
641 hsi_fer : off ok - frame error rate by HSI exceeded adjusted limit
649 mod_los : on ok - modem sync loss – setting “set ala add/rem rfi”
650 rfi_los : on ok - as is by HSI, setting “set ala add/rem rfi”
651 rfi_fer : on ok - as is by HSI, setting “set ala add/rem rfi”
652 idu_temp : on ok - IDU temperature is out of limit (-5-60°C) “set ala add sys”
653 odu_temp : on ok - ODU temperature is out of scope(-25-55°C) “set ala add/rem rad”
654 odu_RxL : on ok - received level on ODU is under adjusted valuation
655 odu comm : on ok - communication error with ODU, setting set ala add rad rad
656 odu_alarm : on ok - alarm set in ODU – details “sh alarm detailed”
660 idu_hwerr : on ok
661 idu_swerr : on ok
First column in the output after the “:” (colon) represents the settings, second column represents
the general status of the system (LED status1) (off = turned-off, on = turned-on) and the third
column indicates the actual error status of the given parameters (OK, err = error).
Control Parameter Setting:
xxx\#set hsi fer 5 - it sets limit for HSI frame error rate to 5 errors in E3 header per minute
xxx\#set e3 fer 5 - it sets limit for rfi frame error rate to 5 errors in CRC per minute
xxx\#set alarm rxalarm - 65 - it sets limit for “radioRxallev” to -65dBm
xxx\#set alarm add all - it sets all controls that affect general status of device (it turns-on all alarms)
xxx\#set alarm add hsi - it turns-on HSI alarms
xxx\#set alarm add rfi - it turns-on modem and rfi alarms
xxx\#set alarm rem g703 all - it turns-off alarms from g703 (e1) ports
xxx\#set alarm add nu 654 - it turns-on on specific alarm (for exam. 654)
Detailed description of the alarm bytes of the ODU and IDU :
xxx|#sh alarm detailed
idu_hwerr : 00000200 - error bits set
idu_hwmask: 000000ff - error bit mask (setting “set alarm hwmask 0xXXX”)
hw alarms : none - text output of alarms after masking (none = OK)
MODEM alarms : 0x19 none - text output of alarms of modems (none = OK)
ODU alarms: 0x00 None - text output of alarms of ODU (none = OK)
The history of errors can be viewed by command “sh alarm dump”. Status is controlled each
second and a row is generated, if change OK->error (E) or conversely (N).
Tsunami™ GX800 Installation and Management Guide 67