User's Manual
Table Of Contents
- Chapter 1 - Introduction
- Chapter 2 – Hardware Overview
- Chapter 3 – Installation and Initialization
- Chapter 4 - Commissioning
- Introduction
- Access Rights
- Restore Defaults
- Configure, Manage and Monitor using Web Browser
- General Screen
- IP Address Setup
- Dual License - Design Type Setup
- Frequency, Modulation and ATPC Setup
- Ethernet Advanced Configuration
- Data Rate Settings for Connected User Interfaces
- Save Configured Parameters
- BER Test – GX800 Link and User Lines Verification
- Analysis of Interference in GX800 link
- Firmware Upgrade, License Upgrade
- Alarms
- SNMP Settings
- IP Management
- Chapter 5 – Troubleshooting
- Chapter 6 - Technical Parameters
- Chapter 7 - Appendix
Number Title Description
600 g703 p1 link No valid E1 signal on p1 port
601 g703 p1 ais Detecting sequence “1” (according to the ITU G.755 norm for E1)
on p1 port
602 g703 p2 link No valid E1 signal on p2 port
603 g703 p2 ais Detecting sequence “1” (according to the ITU G.755 norm for E1)
on p2 port
632 lana1 link No valid signal on LAN A1 port (Gigabit user data port)
636 lanb1 link No valid signal on LAN B1 port (100Mbit management port)
640 hsi los Failure of frame/packet synchronization on HSI interface
(fiber/4W)
641 hsi fer Frame failure of HSI interface over limit
644 mse low Bad MSE (SNR) – threshold can be set
649 mod los Failure of frame/packet synchronization on modem interface
650 rfi los Failure of frame/packet synchronization on packet based
multiplexer (modem)
651 rfi fer Frame failure of RFI interface above limit
652 idu_temp Temperature of indoor unit is above limit (-5 through 60°C)
653 odu_temp Temperature of outdoor unit is above limit (-25 through 60°C)
654 odu_RxL Received level of outdoor unit above limit
655 odu_comm Error while communicating with outdoor unit
656 odu_alarm Outdoor unit has non-zero alarm byte
657 license err License problem
658 safe design N/A for HS – backup system run
659 reset Reset underway
660 hw error Hardware error – with older units set mask of hardware presence
(after firmware update), or servicing by Proxim necessary
661 sw error Software error – try restarting, update firmware and restart
662 system error Non-specified system error – contact Proxim
Example of the printout:
E 649 192.168.3.52 GX800 mod_los Tue Jan 6 05:45:20 2009
event_status – event_ID – IP_address – device_type – event_ name – date_and_time
SNMP Settings
The system permits to set a maximum of three IP addresses to which the SNMP traps will be
sent.
To set the IP addresses, navigate to the main menu “IP” and sub-menu “SNMP”.
Tsunami™ GX800 Installation and Management Guide 45