The STATISTICS screen is displayed which contains the following information:
Status: Indicates the sync status and the received BER pattern
Conf. Speed: Capacity set for BER tester
Act. Speed: Real data rate dedicated for BER (automatically adjusted data rate)
TX Pattern: Set of BER frame type (has to be set the same on both sides)
Bit Count: Overall transmitted bits
Err Count: Overall error bits
Sync Count: Number of synchronizations since the last counters clearance
BER: Error rate
TLE: Time since last error occurrence
TBE: Time between last two errors
EFS: Time of error-free traffic in seconds
ERS: Time elapsed while the link failed in seconds
Data Evaluation:
Clear the BER tester counters and check the results by clicking Refresh button.
For proper functioning of GX800 link, the values of EFS parameter, ERR Count, Sync Count,
BER, TLE, TBE and ERS parameters should be equal to zero.
If the test results vary, and the link (line) fails, it is necessary to verify the link installation and
configuration (verification of connected user line).
For GX800 link test, the same results must be read on both sides of the link.
Tsunami™ GX800 Installation and Management Guide 38
Figure 38: BER Tester Information