!! Note !! For BER test, configure the parameters on both the terminals equally.
After configuring the parameters, click Apply.
User Line BER Test:
For the user line BER test, the full capacity of the line is devoted to BER tester. The BER signal is
directed to the selected channel and sent in the direction of HSI module of the IDU. Use loop on
the line to bring the signal back and verify the line quality.
Select the “ber” option instead of “rfi” in roll down menu of relevant user interface in HSI MUX
section of the following figure:
Next, to monitor the running BER test on GX800 link or user line in the Web Interface, navigate
to main menu “Count” and sub-menu “BER”.
Tsunami™ GX800 Installation and Management Guide 37
Figure 37: BER Test Setup for User Interface