BER Test – GX800 Link and User Lines Verification
Bit Error Rate (BER) test is used to test and verify the quality of GX800 link and the connected
user lines by using internal BER tester.
GX800 BER Test:
A)
We recommend to allocate the full transmission capacity of GX800 to BER test for a limited
period of time. This way, even accidental and momentary errors can be detected. Switch off the
connected user interfaces (check out RFI MUX) and set:
LAN SPEED: 0 Mbps (no capacity for Ethernet)
BER SPEED: 100 Mbps (corresponding to maximum BER test data rate)
B)
During the vivid link operation, it is necessary to allocate least fractional capacity to run the BER
test.
Navigate to main menu “Port” and sub-menu “Parameters” and configure the following
parameters:
• RFI MUX
• LAN SPEED
• BER SPEED
Tsunami™ GX800 Installation and Management Guide 36
Figure 36: BER Test Setup during the Vivid Link Operation