After setting the ACM parameters, check the Enable ACM parameter and click Apply. On doing
so, all the ACM parameters turn Grey. The currently modulation (Actual Modulation) is compared
with the ACM options (ACM0-2). If the current modulation is included in the ACM options, the
system will continue with this modulation without any drop-out (if it is not ACM0, the system will
keep evaluating whether the modulation scheme could not be switched to higher ACM option
(Example, from ACM1 to ACM0).
If the current modulation is not included in ACM options, the Actual Modulation will be switched to
ACM0 option.
!! ATTENTION !! For proper operation of ACM, at least two ACM options (ACM0 and ACM1)
must be selected. The rule is that ACM0 modulation is higher than ACM1 and ACM2!!
The same modulation (ACM options) must be set on both sides of the link.
!! Note !! The ACM can be configured by using either 301 or 303 design types. See Dual
License - Design Type Setup
Click “COMMIT” to save the configured parameters.
Tsunami™ GX800 Installation and Management Guide 31
Figure 31: Modulation with ACM