- Introduction
- Access Rights
- Restore Defaults
- Configure, Manage and Monitor using Web Browser
- General Screen
- IP Address Setup
- Dual License - Design Type Setup
- Frequency, Modulation and ATPC Setup
- Ethernet Advanced Configuration
- Data Rate Settings for Connected User Interfaces
- Save Configured Parameters
- BER Test – GX800 Link and User Lines Verification
- Analysis of Interference in GX800 link
- Firmware Upgrade, License Upgrade
- Alarms
- SNMP Settings
- IP Management
- Chapter 5 – Troubleshooting
- Chapter 6 - Technical Parameters
- Chapter 7 - Appendix
of modulation with a lower data rate there is better self-correcting security and thus a better
sensitivity (revision _01 or _02).
Depending on the type of supplied license (limit for maximum data rate) the modulation type can
be changed (type of modulation can be set / changed up to a maximum transmission capacity).
Microwave link can be ordered in the different licenses in accordance with actual price list and
business policy. Than the transmission capacity can be changed in the range from 10Mbps up to
a maximum data rate of supplied license, maximum 310Mbps.
The modulations are named according to the combination of all the parameters as shown in the
following figure.
To setup the demanded Actual Modulation and Adaptive Modulation (ACM), navigate to main
menu “Radio” and sub-menu “Parameters”. In the parameters screen, navigate to “MODEM
CONFIGURATION”.
Actual Modulation Setup (without ACM):
The Actual Modulation parameter represents the current modulation. For a link without ACM
request, the desired modulation must be set directly in the Actual Modulation field as shown in
the following figure.