User's Manual
Table Of Contents
- Chapter 1 - Introduction
- Chapter 2 – Hardware Overview
- Chapter 3 – Installation and Initialization
- Chapter 4 - Commissioning
- Introduction
- Access Rights
- Restore Defaults
- Configure, Manage and Monitor using Web Browser
- General Screen
- IP Address Setup
- Dual License - Design Type Setup
- Frequency, Modulation and ATPC Setup
- Ethernet Advanced Configuration
- Data Rate Settings for Connected User Interfaces
- Save Configured Parameters
- BER Test – GX800 Link and User Lines Verification
- Analysis of Interference in GX800 link
- Firmware Upgrade, License Upgrade
- Alarms
- SNMP Settings
- IP Management
- Chapter 5 – Troubleshooting
- Chapter 6 - Technical Parameters
- Chapter 7 - Appendix
Polarization ODU Position
Vertical Polarization
Horizontal Polarization
!! ATTENTION !! During installation, please ensure that the ODU waveguide slot matches
with the Antenna ODU Interface slot.
Remote Mount
Follow these steps for remote mount:
1. Fix the ODU remote mounting kit (not supplied with the product package) to the pole
2. On the ODU side of the Flange Adapter, fix the ODU.
3. On the flex side of the Flange Adapter, connect one end of the Waveguide. The other end
of the Waveguide is connected to the antenna.
!! NOTE !! Depending on the frequency, the connection between the antenna flange
adapter and the ODU flange adapter should be through a waveguide or coaxial N-type
SMA connector.
Cabling
Connect IDU and ODU
Connect IDU and ODU by using a low-loss coaxial cable (not supplied with the product package)
with the specified impedance of 50 Ohm, terminated on both sides with the N-type Male
connector. Please note that the maximum cable length between the IDU and ODU should be
200m (Additional distances may be permissible but should be verified with Proxim's technical
team).
Tsunami™ GX800 Installation and Management Guide 12
Figure 6: Remote ODU Mounting