User Manual
Table Of Contents
- Contents
- Introduction
- Installation & Basic Configuration
- Status Information
- Advanced Configuration
- Configuring the AP-600 Using the HTTP Interface
- System
- Network
- Interfaces
- Management
- Filtering
- Ethernet Protocol
- Static MAC
- Static MAC Filter Examples
- Prevent Two Specific Devices from Communicating
- Prevent Multiple Wireless Devices From Communicating With a Single Wired Device
- Prevent All Wireless Devices From Communicating With a Single Wired Device
- Prevent A Wireless Device From Communicating With the Wired Network
- Prevent Messages Destined for a Specific Multicast Group from Being Forwarded to the Wireless LAN
- Static MAC Filter Examples
- Advanced
- TCP/UDP Port
- Alarms
- Bridge
- Security
- RADIUS
- Monitor Information
- Commands
- Troubleshooting
- Troubleshooting Concepts
- Symptoms and Solutions
- Recovery Procedures
- System Alarms (Traps)
- Related Applications
- Command Line Interface (CLI)
- General Notes
- Command Line Interface (CLI) Variations
- CLI Command Types
- Using Tables & User Strings
- Configuring the AP-600 using CLI commands
- Set Basic Configuration Parameters using CLI Commands
- Other Network Settings
- Configure the AP-600 as a DHCP Server
- Configure the DNS Client
- Maintain Client Connections using Link Integrity
- Change your Wireless Interface Settings
- Autochannel Select (ACS)
- [Device Name]>set wif 3 autochannel
[Device Name]>reboot 0 - Enable 2X Turbo Mode (AP-600a Only)
- [Device Name]>set wif 3 turbo
[Device Name]>reboot 0 - Enable/Disable Interference Robustness (AP-600b Only)
- Enable/Disable Closed System (AP-600b Only)
- Enable/Disable Load Balancing (AP-600b Only)
- Enable/Disable Medium Density Distribution (AP-600b Only)
- Set the Distance Between APs (AP-600b Only)
- Set the Multicast Rate (AP-600b Only)
- Set Ethernet Speed and Transmission Mode
- Set Interface Management Services
- Configure Syslog
- Configure Intra BSS
- Configure MAC Access Control
- Configure 802.1x Authentication
- Set RADIUS Parameters
- CLI Monitoring Parameters
- Parameter Tables
- ASCII Character Chart
- Specifications
- Technical Support
Installation & Basic Configuration
24
3. Set IP Address Type to Static.
4. Enter a static IP Address for the AP-600 in the field provided. You must assign the unit a unique address
that is valid on your IP subnet. Contact your network administrator if you need assistance selecting an IP
address for the unit.
5. Enter your network’s Subnet Mask in the field provided.
6. Enter your network’s Gateway IP Address in the field provided.
7. Enter the SNMP Read/Write password in the Read/Write Password field (for new units, the default
SNMP Read/Write password is “public”).
127(
127(127(
127(
The TFTP Server IP Address and Image File Name fields are only available if ScanTool detects that the
AP-600 does not have a valid software image installed. See Client Connection Problems.
8. Click OK to save your changes.
— Result: The Access Point will reboot automatically and any changes you made will take effect.
9. When prompted, click OK a second time to return to the
Scan List
screen.
10. Click Cancel to close the ScanTool.
11. Proceed to Setup Wizard for information on how to access the HTTP interface.
Setup Wizard
The first time you connect to an AP-600’s HTTP interface, the Setup Wizard launches automatically. The Setup Wizard
provides step-by-step instructions for how to configure the Access Point’s basic operating parameter, such as Network
Name, IP parameters, system parameters, and management passwords.
Setup Wizard Instructions
Follow these steps to access the Access Point’s HTTP interface and launch the Setup Wizard:
1. Open a Web browser on a network computer.
127(
127(127(
127(
The HTTP interface supports the following Web browser:
• Microsoft Internet Explorer 5.5 or later
• Netscape 4.x or later
2. If necessary, disable the browser’s Internet proxy settings. For Internet Explorer users, follow these steps:
– Select Tools > Internet Options....
– Click the Connections tab.
– Click LAN Settings....
– If necessary, remove the check mark from the Use a proxy server box.
– Click OK twice to save your changes and return to Internet Explorer.
3. Enter the Access Point’s IP address in the browser’s Address field and press Enter.
– This is either the dynamic IP address assigned by a network DHCP server or the static IP address you
manually configured. See ScanTool for information on how to determine the unit’s IP address and manually
configure a new IP address, if necessary.
– Result: The
Enter Network Password
screen appears.
4. Enter the HTTP password in the Password field. Leave the User Name field blank. For new units, the default
HTTP password is “public”.
– Result: The Setup Wizard will launch automatically.