User Manual
Table Of Contents
- Contents
- Introduction
- Installation & Basic Configuration
- Status Information
- Advanced Configuration
- Configuring the AP-600 Using the HTTP Interface
- System
- Network
- Interfaces
- Management
- Filtering
- Ethernet Protocol
- Static MAC
- Static MAC Filter Examples
- Prevent Two Specific Devices from Communicating
- Prevent Multiple Wireless Devices From Communicating With a Single Wired Device
- Prevent All Wireless Devices From Communicating With a Single Wired Device
- Prevent A Wireless Device From Communicating With the Wired Network
- Prevent Messages Destined for a Specific Multicast Group from Being Forwarded to the Wireless LAN
- Static MAC Filter Examples
- Advanced
- TCP/UDP Port
- Alarms
- Bridge
- Security
- RADIUS
- Monitor Information
- Commands
- Troubleshooting
- Troubleshooting Concepts
- Symptoms and Solutions
- Recovery Procedures
- System Alarms (Traps)
- Related Applications
- Command Line Interface (CLI)
- General Notes
- Command Line Interface (CLI) Variations
- CLI Command Types
- Using Tables & User Strings
- Configuring the AP-600 using CLI commands
- Set Basic Configuration Parameters using CLI Commands
- Other Network Settings
- Configure the AP-600 as a DHCP Server
- Configure the DNS Client
- Maintain Client Connections using Link Integrity
- Change your Wireless Interface Settings
- Autochannel Select (ACS)
- [Device Name]>set wif 3 autochannel
[Device Name]>reboot 0 - Enable 2X Turbo Mode (AP-600a Only)
- [Device Name]>set wif 3 turbo
[Device Name]>reboot 0 - Enable/Disable Interference Robustness (AP-600b Only)
- Enable/Disable Closed System (AP-600b Only)
- Enable/Disable Load Balancing (AP-600b Only)
- Enable/Disable Medium Density Distribution (AP-600b Only)
- Set the Distance Between APs (AP-600b Only)
- Set the Multicast Rate (AP-600b Only)
- Set Ethernet Speed and Transmission Mode
- Set Interface Management Services
- Configure Syslog
- Configure Intra BSS
- Configure MAC Access Control
- Configure 802.1x Authentication
- Set RADIUS Parameters
- CLI Monitoring Parameters
- Parameter Tables
- ASCII Character Chart
- Specifications
- Technical Support
129
C
Specifications
In This Appendix
• Hardware Specifications
• Radio Specifications
Hardware Specifications
Physical Specifications
AP-600 Unit (without metal base)
Dimensions (H x W x L) = 3.5 x 17 x 21.5 cm (1.5 x 6.75 x 8.5 in.)
Weight = 0.68 kg (1.50 lb.)
Electrical Specifications
Using the Power Adapter
Voltage (Input) = 100 to 240 VAC (50-60 Hz) @ 0.4 A
Voltage (Output) = 12 VDC
Power Consumption = 10 Watts
Using Active Ethernet
Input Voltage = 42 to 60 VDC
Output Current = 200mA at 48V
Power Consumption = 10 Watts
Environmental Specifications
AP-600 Unit
Operating Temperature = 0° to +55°C ambient temperature (without plastic cabinet)
Operating Humidity = 95% maximum (non condensing)
Storage Temperature = -20 to +75°C ambient temperature
Storage Humidity = 95% maximum (non condensing)
Ethernet Interface
10/100 Base-TX, RJ-45 female socket
Serial Port Interface
Standard RS-232C interface with DB-9, female connector