Specifications

Basic Management Tsunami MP.11 5012/5054-SUI Installation and Management
Rebooting and Resetting
48
Rebooting and Resetting
All configuration changes require a restart unless otherwise stated. New features explicitly state whether a reboot is
required or not. You can restart the unit with the Reboot command; see the first method described in the following sub-
sections.
Most changes you make become effective only when the 5012/5054-SUI is rebooted. A reboot stores configuration
information in non-volatile memory and then restarts the 5012/5054-SUI with the new values (see Soft Reset to Factory
Default).
In some cases, the 5012/5054-SUI reminds you that a reboot is required for a change to take effect. You need not reboot
immediately; you can reboot after you have made all your changes.
NOTE: Saving of the unit’s configuration occurs only during a controlled reboot or by specifically issuing the CLI Save
command. If you make changes to settings without a controlled reboot (command) and you have not issued the
Save command, a power outage would wipe out all changes since the last reboot. For example, entering static
routes takes effect immediately; however, the routes are not saved until the unit has gone through a controlled
reboot. Proxim strongly recommends saving your settings immediately when you finish making changes.
Rebooting
When you reboot, the changes you have made become effective and the 5012/5054-SUI is restarted. The changes are
saved automatically in non-volatile memory before the actual reboot takes place.
To reboot, click Commands > Reboot > Reboot button. The 5012/5054-SUI restarts the embedded software. During
reboot, you are redirected to a page showing a countdown timer, and you are redirected to the Status page after the
timer counts down to 0 (zero). The CLI is disconnected during reboot. This means that a new telnet session must be
started.
Resetting Hardware
If the unit does not respond for some reason and you are not able to reboot, you can restart by means of a hardware
reset. This restarts the hardware and embedded software. The last saved configuration is used. Any changes that you
have made since then are lost. To reset the hardware, press and release the RESET button on the 5012/5054-SUI unit
with, for example, a pencil.
Soft Reset to Factory Default
If necessary, you can reset the unit to the factory default settings. This must be done only when you are experiencing
problems. Resetting to the default settings requires you to reconfigure the unit. To reset to factory default settings:
1. Click Commands > Reset.
2. Click the Reset to Factory Default button. The device configuration parameter values are reset to their factory
default values.
Reset button