Specifications

System Overview Tsunami MP.11 5012/5054-SUI Installation and Management
Virtual Local Area Networks (VLANs)
40
BSU Function – Mixed
Mode
SU Function – Mixed Mode SU Function – Trunk Mode SU Function – Access
Mode
Up to 256 VLAN IDs can
be configured on a BSU.
BSU allows all untagged
frames received from the
Ethernet interface or from
any of the associated SUs
(unexpected).
If a valid VLAN ID is
configured, BSU forwards
only VLAN-tagged frames
received from the Ethernet
interface or from any of the
associated SUs that are
tagged with the configured
VLAN IDs; it discards all
other tagged frames.
If a valid management
VLAN ID is configured,
BSU allows only
management frames
tagged with the configured
management VLAN ID to
access it.
If a valid management
VLAN ID is configured,
BSU tags all management
frames generated by the
BSU with the configured
management VLAN ID and
priority.
If the management VLAN
ID is configured as -1
(untagged), BSU allows
only untagged
management frames to
access it.
Up to 16 VLAN IDs can be
configured on an SU.
SU accepts all untagged
frames received from the
Ethernet interface or from
the BSU (unexpected).
If a valid VLAN ID is
configured, SU forwards
only VLAN-tagged frames
received from the Ethernet
interface or from the BSU
that are tagged with the
configured VLAN IDs; it
discards all other tagged
frames.
If a valid management
VLAN ID is configured, SU
allows only management
frames tagged with the
configured management
VLAN ID to access it.
If a valid management
VLAN ID is configured, SU
tags all management
frames generated by the
SU with the configured
management VLAN ID and
priority.
If the management VLAN
ID is configured as -1
(untagged), SU allows only
untagged management
frames to access it.
Up to 16 VLAN IDs can be
configured on an SU.
SU discards all untagged
frames received from the
Ethernet interface or from
the BSU (unexpected).
If a valid VLAN ID is
configured, SU forwards
only VLAN-tagged frames
received from the Ethernet
interface or from the BSU
that are tagged with the
configured VLAN IDs; it
discards all other tagged
frames.
If a valid management
VLAN ID is configured, SU
allows only management
frames tagged with the
configured management
VLAN ID to access it.
If a valid management
VLAN ID is configured, SU
tags all management
frames generated by the
SU with the configured
management VLAN ID and
priority.
If the management VLAN
ID is configured as -1
(untagged), SU allows only
untagged management
frames to access it.
SU discards all tagged
frames received from the
Ethernet interface and all
untagged frames received
from the BSU
(unexpected).
SU tags all untagged
frames received from the
Ethernet interface with the
configured Access VLAN
ID and forwards them to
the BSU.
SU untags all tagged
frames received from the
BSU that are tagged with
the configured Access
VLAN ID and forwards
them to the Ethernet
interface; it discards all
other tagged frames from
the BSU.
If a valid management
VLAN ID is configured, SU
allows only management
frames tagged with the
configured management
VLAN ID to access it from
the BSU.
If a valid management
VLAN ID is configured, SU
tags all management
frames generated by the
SU with the configured
management VLAN ID and
priority and forwards them
to the BSU.
If the management VLAN
ID is configured as -1
(untagged), SU allows only
untagged management
frames to access it from
the BSU.
SU allows only untagged
management frames to
access it from the Ethernet
interface, regardless of the
value of the management
VLAN ID.