Specifications
Procedures Tsunami MP.11 5012/5054-SUI Installation and Management
Forced Reload
121
Forced Reload
With Forced Reload, you reset the 5012/5054-SUI to the factory default settings and erase the embedded software. Use
this procedure only as last resort if the 5012/5054-SUI does not boot and the Hard Reset to Factory Default” procedure
did not help. If you perform a Forced Reload, you must download a new image file with the Bootloader (see Image File
Download with the Bootloader below).
CAUTION: The following procedure erases the embedded software of the 5012/5054-SUI. This software image must be
reloaded through an Ethernet connection with a TFTP server. The image filename to be downloaded can be
configured with ScanTool through the Ethernet interface to make the 5012/5054-SUI functional again.
To do a forced reload:
1. Press the RESET button on the back of the 5012/5054-SUI unit; the 5012/5054-SUI resets and the LEDs flash.
2. Immediately press and hold the RELOAD button on the unit for about 20 seconds. Now image and configuration are
deleted from the unit.
3. Follow the procedure described in Image File Download with the Bootloader to download an image file.