Specifications

Installation and Initialization MP.11 5054 (MP11.a) Installation and Management
Installation Procedure
28
Step 7: Power on the Unit
The 5054 can be powered by a power supply (just plug the power cord of the power supply into an AC power outlet), or
by PoE (connect a PoE splitter to the Ethernet cabling).
Step 8: View LEDs
When the unit is powered on, the 5054 performs startup diagnostics. When startup is completed, the LEDs show the
operational state of the 5054 (see the following figure).
The following table shows the status of the LEDs when the 5054 is operational (the fourth LED is only used during
Dynamic Frequency Selection on a BSU).
LED Power Ethernet Link Wireless Link Dynamic Frequency
Selection
Off Power is not present or
is malfunctioning.
Not connected. Wireless interface is up
properly but no wireless
link established.
Green Power is present; the
unit is operational.
Connected at 10 Mbps. Immediately after
connecting a wireless
link.
Blinking Green N/A Data is being sent at 10
Mbps.
Data is being sent or
the wireless interface is
initializing after reboot
(less than two minutes).
Scanning for channel.
Amber The unit is initializing
after reboot (less than
two minutes); it cannot
get a dynamic IP
address.
Connected at 100
Mbps, or the unit is
initializing after reboot
(less than two minutes).
N/A N/A
Blinking Amber N/A Data is being sent at
100 Mbps.
N/A N/A
Red A fatal error in the unit. An error in data
transfer.
There is a fatal error on
the wireless interface.
N/A
Power
Ethernet Link
Wireless Link
Dynamic
Frequency
Selection