Specifications
Installation and Initialization MP.11 5054 (MP11.a) Installation and Management
Installation Procedure
18
Installation Procedure
NOTES:
• The Configure System window provides a selectable Country field that automatically provides the allowed
bandwidth and frequencies for the selected country as well as, where applicable, Dynamic Frequency Selection
(DFS) and Transmit Power Control (TPC).
• Non-US installers should not add an antenna system until the Country is selected, the unit is rebooted, and the
proper power level is configured.
• Be sure to read the Release Notes file on the product CD as it contains software version and driver information
that may not have been available when this document was produced.
• When using PoE, use only a power injector that meets these requirements:
– UL-Listed/ITE (NWGQ)
– Limited Power Source Output per UL/IEC 60950
– CE-marked
– Approved for Power-over-Ethernet
– Rated output, 48 Vdc/0.42 A
– Pinout follows 802.3af standard for mid-span devices
The following installation procedure provides instructions for attaching both the power and Ethernet connectors. In
situations without an external antenna (for example, during a desk tryout), the antenna cable is not required.
See the following steps:
• Step 1: Choose a Location
IMPORTANT:
Before installing and using this product, see Safety and Regulatory Compliance Information on the
product CD.
IMPORTANT:
All units must be installed by a suitably trained professional installation technician or by a qualified
installation service.
WARNING:
For your own safety, when using DC power, use only the power adaptor supplied with the unit.
WARNING:
The metal case of the unit must be grounded through the ground connection that is provided on the
metal case. The antenna grounding, the surge arrestor, and the 5054 unit housing must be bonded
together and grounded in one location to avoid ground current loops.