Specifications
Technical Specifications MP.11 5054 (MP.11a) Installation and Management
Maximum Throughput
178
Maximum Throughput
Latency
Transmit Power Settings
• Output Power Attenuation: 0 - 18 dB, in 1 dB steps
Modulation
40 MHz Channels
Turbo Mode
(Non-DFS US Only)
20 MHz Channels
Standard Mode
64QAM ¾ -66 dBm @ 108 Mbps -69 dBm @ 54 Mbps
64QAM ½ -68 dBm @ 96 Mbps -72 dBm @ 48 Mbps
16QAM ¾ -75 dBm @ 72 Mbps -77 dBm @ 36 Mbps
16QAM ½ -78 dBm @ 48 Mbps -80 dBm @ 24 Mbps
QPSK ¾ -81 dBm @ 36 Mbps -83 dBm @ 18 Mbps
QPSK ½ -83 dBm @ 24 Mbps -86 dBm @ 12 Mbps
BPSK ¾ -84 dBm @ 18 Mbps -87 dBm @ 9 Mbps
BPSK ½ -85 dBm @ 12 Mbps -88 dBm @ 6 Mbps
Data Rate 40 MHz Channels
Turbo Mode
(US Non-DFS Only)
20 MHz Channels
Standard Mode
108 Mbps
Turbo 54
35 Mbps —
96 Mbps
Turbo 48
35 Mbps —
72 Mbps
Turbo 36
35 Mbps —
48 Mbps
Turbo 24
27 Mbps —
36 Mbps
Turbo 18
22 Mbps —
24 Mbps
Turbo 12
16 Mbps —
54 Mbps — 33 Mbps
48 Mbps — 32 Mbps
36 Mbps — 27 Mbps
24 Mbps — 19 Mbps
18 Mbps — 14 Mbps
12 Mbps — 9 Mbps
9 Mbps — 7 Mbps
6 Mbps — 5 Mbps
Category Specification
Typical at Max Throughput 10 ms (as measured with test equipment under controlled lab
conditions and best performing packet size)