Specifications
Configuration MP.11 5054 (MP.11a) Installation and Management
QoS (Quality of Service) Parameters (BSU Only)
114
To add entries to the SFC Table, click the Add Table Entries button.
The following parameters are configurable:
• SF Name: Enter the name of the SF class you want to add.
• SF Schd Type: This field can be set to BE (Best Effort) or RtPS (Real-Time Polling Service).
• SF Direction: This field can be set to Downlink (traffic from BSU to SU) or Uplink (traffic from SU to BSU).
• MIR (Maximum Information Rate): The maximum sustained data rate specified in units of 1 Kbps from 8 Kbps up to
the maximum rate of 108000 Kbps per SU.
• CIR (Committed Information Rate): The minimum reserved traffic rate specified in units of 1 Kbps from 0 Kbps up to
the maximum rate of 10000 Kbps per SU.
• Latency: The maximum allowed latency specified in increments of 5 ms steps from a minimum of 5 ms up to a
maximum of 100 ms.
• Jitter: The maximum tolerable jitter specified in increments of 5 ms steps from a minimum of 0 ms up to the Maximum
Latency (in ms).
• Priority: The priority of this SFC from zero (0) to seven (7), 0 being the lowest, 7 being the highest.
• Number of Frames per Burst: The maximum number of data messages in a Multi-Frame burst from one (1) to four
(4), which affects the percentage of the maximum throughput of the system according to following table.