Field Descriptions
You can enter the following details:
System Name
This is the system name for easy identification of the BSU or SU. The System Name field is limited to a
length of 32 bytes. Use the system name of a BSU to configure the Base Station System Name parameter
on an SU if you want the SU to register only with this BSU. If the Base Station System Name is left blank
on the SU, it can register with any Base Station that has a matching Network Name and Network Secret.
Country
The Dynamic Frequency Selection (DFS) and Transmit Power Control (TPC) features are enabled
automatically when you choose a country with a regulatory domain that requires them. The Country
selection pre-selects and displays only the allowed frequencies for the selected country.
Click the Configure button, the Interfaces tab, and the Wireless sub-tab to see the channel/frequency list for
the selected Country.
Note: Units sold in the United States are pre-configured to scan and display only the outdoor frequencies
permitted by the FCC. No other Country selections, channels, or frequencies can be configured.
Units sold outside of the United States and Canada support the selection of a Country by the
professional installer. If you change the Country, a reboot of the unit is necessary for the upgrade to
take place.
Dynamic Frequency Selection is not supported in 2.4 GHz operational mode; it is supported on Model 5054-R
units only.
Support for the 5.25 – 5.35 GHz and 5.725 – 5.825 GHz frequency bands is provided with a single country
selection, UNITED STATES (US), which does not provide DFS capability in these frequency bands.
For a non US-only device, the default country selected is United Kingdom (GB).
Notes: (1) The channel center frequencies are not regulated; only the band edge frequencies are
regulated.
(2) If, before upgrade, US was selected as a country for a non US-Only device (which is an
incorrect configuration), the country is changed automatically to United Kingdom upon upgrade.
See “Appendix A. Country Code/Channels” Tables on page 131 for a list of country codes.
Location
This field can be used to describe the unit’s location, for example “Main Lobby.”
Contact Name, Contact Email, and Contact Phone
In these fields, you can enter the details of the person to contact.
Mode of Operation
This field lets you choose one of two operating modes: Bridge mode or Routing mode.
Temperature Logging Interval
This field lets you configure the temperature logging interval (in 5-minute intervals). See “Monitor: 12)
Temperature Log”
on page 115 for more information.
The static fields on this window are described as follows:
ObjectID
This field shows the OID of the product name in the MIB.
Ethernet MAC Address
The MAC address of the Ethernet interface of the device.
Descriptor
Shows the product name and firmware build version.
Up Time