Chapter 3. Management Overview 22
The enterprise MIB (orinoco.mib) defines the read and read/write objects you can view or configure using
SNMP. These objects correspond to most of the settings and statistics that are available with the other
management interfaces. See the enterprise MIB for more information; the MIB can be opened with any text
editor, such as Microsoft Word, Notepad, and WordPad. See “Configure SNMP Parameters”
on page 67 for
setup procedures.
For the serial connection, you can use only the CLI to configure and manage the 5054-R or 2454-R units.
The other connections allow the use of the Web Interface, SNMP, and the CLI; however, you must know the
IP address of the unit before you can use these other connections, See “IP Address” below for more
information.
IP ADDRESS
Because each network is different, an IP address suitable for your network must be assigned to the unit. You
must know this IP address to configure and manage the unit through its Web Interface, SNMP, or the CLI. You
can manage other basic parameters as well. ScanTool is included on the documentation and software CD to
assist you in finding and changing the unit’s IP address.
The unit can use either a static or dynamic IP address. The unit either obtains its IP address automatically
through DHCP (dynamic IP address) or it must be set manually (static IP address).
With ScanTool (a software utility that is included on the product installation CD), you can find out the current IP
address of the unit and, if necessary, change it so that is appropriate for your network. The units are shipped with
the static IP address 10.0.0.1 configured.
ScanTool lets you find the IP address of a Tsunami MP.11 5054-R or 2454-R by referencing the MAC address in
a Scan List, or to assign an IP address if the correct one has not been assigned. The tool automatically detects
the units installed on your network segment, regardless of IP address, and lets you configure each unit’s IP
settings. In addition, you can use ScanTool to download new software to a unit that does not have a valid
software image installed.
Setting the IP Address
If you want to set the IP address:
1. Run ScanTool on a computer connected to the same LAN subnet as the unit, or a computer directly
connected to the unit with a cross-over Ethernet cable. ScanTool (scantool.exe) has been installed on your
computer at the following location: c:\Program Files\Tsunami\MP.11
ScanTool scans the subnet for 5054-R and 2454-R units and displays a list of the units it finds in the main
window. The following figure is an example of the main window. If necessary, click Rescan to re-scan the
subnet and update the display. You can assign a new IP address to one unit, even if more than one unit has
the same (default) IP address 10.0.0.1, but the new IP address must be unique to allow use of the
management interfaces.