User's Manual

Tsunami MP.11 2454-R, 5054-R, and 5054-R-LR Installation and Management
Chapter 2. Installation 19
set aad disable
Disables Antenna Alignment Display (Ctrl-C also disables AAD).
9) COMPLETING INSTALLATION
Be sure you have re-installed the waterproof caps on the serial and Ethernet port connections.
Caution! Do not over-tighten the rear nut on the waterproof connector assembly. Over-tightening can
cause the Cat 5 cable to crush and can subsequently damage the power injector or the unit.
The recommended torque for the rear nut is 25 to 30 inch-pounds(lbf inches) or 28.8 to 34.6
centimeter-kilograms (kgf cm).
OTHER CONNECTIONS
Power and Ethernet Connection
Recommended Cable
Function
Type
Impedance
Recommended cables
Maximum Distance
Connector type, unit end
Connector type, power & Ethernet
adapter end
Power (DC) and Ethernet connection
Cat5, UV-shielded and outdoor-rated
100 ohms
4 UTP, 24 AWG, UL rated
330 feet / 100 meters
RJ45 female, weatherized using weatherproof connector
RJ45
Serial Connection
The serial connection is made with an RJ11 to DB9 connector (also referred to as a “dongle”). Connect the RJ11
end to the unit and connect the serial (DB9) end to your PC to assist you in aligning the antenna and to issue CLI
commands.
The connections are:
(D-shell - RJ-11)
1 NC
2 2
3 4
4 NC
5 1 + 3 + 5
6 6
7 NC
8 NC
9 NC