User's Manual
Tsunami MP.11 2454-R, 5054-R, and 5054-R-LR Installation and Management
Chapter 2. Installation 14
5. Attach bracket connector (C) to bracket (E) with the screw and nut provided.
3) CONNECT THE CABLES
1. If you have not already done so, connect the normal RJ45 connector on an outdoor-rated Cat5 cable to the
“Data & Power Out” port on the power injector.
2. Attach the other end of the Cat 5 cable with RJ45 connector to the Power and Ethernet port on the back of the
unit (see the following figure). Note that the first attachment of this cable is meant to verify operation and
configure the unit; the final attachment and weatherproofing are to be done after the unit has been installed in
the location at which it will operate. Do not tighten the connector nut; do not use a wrench to tighten
the connector!
3. To connect the unit through a hub or a switch to a PC, use a straight-through Ethernet cable between the
network interface card in the PC and the hub, and between the hub and the RJ45 “Data In” port on the PoE
adapter.
(TORQUE 130 IN-LBS)