Service Manual

14
CX-Series Service Manual
D.
Hardware Installation Steps
STEP 1
STEP 4 (To Re-hand if Necessary)
Install the latch in the door with the SP2 screws provided. The
latch tube prongs should project into the chassis hole.
1. To re-hand the lock chassis, begin by removing both
the through bolt posts. See arrows below.
2. Remove the lock chassis and rotate both the internal
mechanics and the chassis 180 degrees to
accommodate the hand of the door. You will not need
to remove the exterior gasket or backplate.
3. Replace through bolt posts.
STEP 2
Install the strike plate with the SP3 screws provided, checking
to make sure that the position of the deadlocking plunger is
aligned against the strike plate. See Appendix A for Door
Preparation Instructions.
STEP 3
STEP 5
Ensure the cable from the exterior board is properly routed
through the cylindrical lock chassis by first inserting one edge,
then pressing the other into the cable slot.
Slide the lock chassis through the chassis hole in the door,
ensuring that the chassis engages the latch.
Re-handed lock chassis to
accommodate left-handed
(RHR) door