User manual
Fibre to SAS/SATA II RAID Subsystem
User Manual 
141 
3.  Additional Information 
a.  When a disk has failed in Enclosure#1 Slot#1 and you try to power off 
Enclosure#1 Slot#1 using the command “PowerOffDisk Enclosure#1 
Slot#1”, and then remove
 the Disk from the slot and insert a new Disk, 
the Disk will not power on because the Disk Slot is still in power off 
state. 
You need to use the command “PowerOnDisk Enclosure#1 Slot#1” to 
power on the Disk Slot. 
NOTE: Sometimes the “PowerOffDisk” and “PowerOnDisk” 
command will need to wait for several seconds before command 
execution is completed (web GUI is updated), specially when the 
Raid subsystem is active or busy. 
b.  When a disk has failed in Enclosure#1 Slot#1 and you try to power off 
Enclosure#1 Slot#1 using the command “PowerOffDisk Enclosure#1 
Slot#1”, remove the failed disk, and then power-cycle the Raid 
subsystem, the Disk Slot will be powered on. If you insert a new Disk 
in Enclosure#1 Slot#1, the Disk will be detected. Take note that using 
“Restart Controller” function, instead of power-cycle, still will not 
power on the Disk Slot. 
NOTE: Sometimes the “PowerOffDisk” command will need to wait 
for several seconds before command execution is completed (web 
GUI is updated), specially when the Raid subsystem is active or 
busy. 