Terminal Descriptions
+12V
T/R
-
LK -
(GND)
LK+(COM)
N.O.
EB+
EB
-
T/R+
PROR11
Connection
Board
+12V
T/R
-
L1
L2
PA
1
2
LK - (GND)
LK+(COM)
N.O.
EB+
EB
-
1
2
3
T/R+
L1 L 2
PA
PB
BUS
3
PB
BUS
•
+12V:
12VDC power output.
•
LK-(GND):
power ground.
•
LK+(COM):
electronical load activation relay contact common.
•
NO.:
electronical load activation relay normally open contact (the default setting for this terminal is NO, this
terminal can be configured to NC, normally
-
closed contact by the CHALLENGER PRO CONFIG
software). That means, by default, only the power
-
to
-
unlock type of electronic lock can be connected to the
COM and NO terminal, if using the power
-
off
-
to
-
unlock type locks, the NO terminal must be set to NC contact by
the CHALLENGER PRO CONFIG software.
•
EB+:
Exit button.
•
EB-:
Exit buton.
•
JP-LK:
For electronic lock safety type setting(refer to Door Station Lock Connections).
•
T/R-:
USB
-
RS485 communication terminal negative.
•
T/R+:
USB
-
RS485 communication terminal positive.
•
SET:
DIP switches for system configurations.
•
PA:
Press once to sent the name list to Monitor; press and hold for 3 seconds to add Master card.
•
PB:
Press once to search the Right line Monitor; press and hold for 3 seconds to search left line Monitor.
•
Bus(
L1,L2
):
non
-
polarity bus line.
Door Station wiring
This example is one Door Station wiring, note that the lock used here is a 12Vdc 300mA power
-
to
-
unlock type.
-
+12V
LK - (GND)
LK+(COM)
+
N.O.
EB+
EB -
T/R -
T/R+
Outlet Button
1
L1 L2
PA
2
3
PB
Connect to PROPS or PROPS-4