Specifications
CHALLENGER PRO
-
System
40
Slave Address Explained
2
-
wire CHALLENGER PRO system is capable of connecting up to 4 Monitors in one apartment, which means they will
have the same
User Code, and will be called simultaneously. In this condition, the Monitors should be programmed as below:
• 1. All the Monitors of same apartment must be programmed with the same User Code on the DIP switches.
• 2. There is only one master Monitor in the one apartment, and the Slave Address of the master Monitor is set to 0.
Each Slave Monitor should be set from 1~3.
• By default, Monitor’s Slave Address is pre
-
set to 0(master Monitor).
• When Door Station calls, only the master Monitor will turn on the screen, the slave Monitor will only ring.
Master Monitor Slave Monitor 1 Slave Monitor 2 Slave Monitor
3
Slave
Address
0
Slave
Address
1
Slave
Address
2
Slave
Address
3
Please note, when called by Door Station, all Monitors will ring, however, only the Monitor which Sub User Code was
programmed to 0 will turn on the screen.
Programming Slave User Code is by means of Monitor Menu, in the Main
- -
> Setup
- -
> Advance Set page(a password
will be required before enter the setting, the password is:
2008
), operate as below:
• The Slave Addr Set item is for the master and slave
Slave Addr
Set -- 0
Guard
Unit Set -- 0
Date
and
Time
set...
Other
settings...
Informations...
Exit
user code setting, default is set to 0 for master user
code. It can be change to 1, 2 or 3.
• The Guard Unit Set item is for Guard Unit Monitor
setting, the default it set to 0, if set to 1, this Monitor is
become a Guard Unit Monitor.
H o m e
I
n
t
e
l
l
ig e n t S y s
t
e
m