Specifications

CHALLENGER PRO
-
System
40
Slave Address Explained
2
-
wire CHALLENGER PRO system is capable of connecting up to 4 Monitors in one apartment, which means they will
have the same
User Code, and will be called simultaneously. In this condition, the Monitors should be programmed as below:
1. All the Monitors of same apartment must be programmed with the same User Code on the DIP switches.
2. There is only one master Monitor in the one apartment, and the Slave Address of the master Monitor is set to 0.
Each Slave Monitor should be set from 1~3.
By default, Monitor’s Slave Address is pre
-
set to 0(master Monitor).
When Door Station calls, only the master Monitor will turn on the screen, the slave Monitor will only ring.
Master Monitor Slave Monitor 1 Slave Monitor 2 Slave Monitor
3
Slave
Address
0
Slave
Address
1
Slave
Address
2
Slave
Address
3
Please note, when called by Door Station, all Monitors will ring, however, only the Monitor which Sub User Code was
programmed to 0 will turn on the screen.
Programming Slave User Code is by means of Monitor Menu, in the Main
- -
> Setup
- -
> Advance Set page(a password
will be required before enter the setting, the password is:
2008
), operate as below:
The Slave Addr Set item is for the master and slave
Slave Addr
Set -- 0
Guard
Unit Set -- 0
Date
and
Time
set...
Other
settings...
Informations...
Exit
user code setting, default is set to 0 for master user
code. It can be change to 1, 2 or 3.
The Guard Unit Set item is for Guard Unit Monitor
setting, the default it set to 0, if set to 1, this Monitor is
become a Guard Unit Monitor.
H o m e
I
n
t
e
l
l
ig e n t S y s
t
e
m