Operation Manual
6
DIP switch to “ON” means to “1”,DIP switch to "OFF" means "0".
The baud rate and control protocol as the following table:
NO. 1 2 3 4
Baud rate
(BPS)
OFF OFF PELCO-P
ON OFF PELCO-D
OFF ON PELCO-D/P
ON ON PELCO-D/P
Control
Protocol
OFF OFF 9600
ON ON 9600
OFF ON 4800
ON OFF 2400
8-bit DIP switch is used to set the camera's address coding. Address set
binary mode can be set to a total of 256 different dome camera address
coding, see coding table address.
Camera
address
Camera address coding form
1 2 3 4 5 6 7 8
0 OFF OFF OFF OFF OFF OFF OFF OFF
1 ON OFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF
5 ON OFF ON OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF
7 ON ON ON OFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF
9 ON OFF OFF ON OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF
11 ON ON OFF ON OFF OFF OFF OFF
12 OFF OFF ON ON OFF OFF OFF OFF
… … … … … … … … …
246 OFF ON ON OFF ON ON ON ON
247 ON ON ON OFF ON ON ON ON