Datasheet

edit mode and create a VolumeReg object with the name CVolMerk1. The volume identity for user
class volumes should chosen in the interval 0.0.2-249.1-254 and we choose 0.0.99.20 as the identity
for our class volume. In the attribute Project the name of our project is stated, mars2.
Fig Classvolume registration
Open the classvolume
Next step is to configure and create the class volume in the project. This is done in the directory
volume.
We enter the directory volume
> pwrs
in edit mode and create an object of type ClassVolumeConfig in the volume hierarchy. The object is
named with the volume name CVolMerk1. After saving and leaving edit mode we can open the
class volume by activating OpenClassEditor... in the popup menu of the object.