4.3 RECEIVER ANTENNA POSTION
The sensitivity of the receiver antenna is similar to the transmitter antenna. The waves are received optimally on the
sides of the active part of the antenna (part measuring 30 mm at the end of the black extension measuring about 11 cm).
The active part of the antenna must be installed strictly straight and away from any electrically conductive element
(metal, carbon ...). Otherwise, the effect of "masking" occurs, greatly reducing the range.
4.4 WIRING THE RECEIVER
The receiver has 7 connectors. The connector marked is intended for power supply. The 6 other connectors
marked to are intend to be connected to the servos and ESC following :
4.5 RECEIVER POWER SUPPLY
The installation of the receiver and servos in the model deserves your attention. These materials are nominally designed
to operate with a supply voltage between 4.8 V and 8,4 V.
The power supply must be connected to the connector marked on the receiver. It is essential to insert the
power connector in strict accordance with the position of the negative supply, spotted on the edge of the receiver. Any
errors or delays meaning a pin up or down can lead to immediate destruction of the receptor and / or servos connected
to it.
The destruction caused by the receiver or offset reverse connection is not covered by warranty.
In practice, there are two main ways to feed the reception of a model. They differ mainly by the fact that the battery
powers the reception or on the contrary by the presence of a regulator.
2 CARACTERISTIQUES
4 OVERALL FEATURES
S
S
Strong. Level of
emitted waves is
high.
W
Weak. Level of
emitted waves is low.
S
W
S
Sensitive.
Level of received
waves is high.
W
Weak. Level of
received waves is
low.
« EXTENSION » part
« ACTIVE »
Part
CH1 CH6
INDICATION FONCTION
CH1 AILERON
CH2 PROFONDEUR
CH3 GAZ
CH4 DIRECTION
CH5 TRAIN
CH6 VOLET
BAT ALIMENTATION
The marking on the edge of the receiver shows the connector pinouts.
It is imperative to respect strictly, otherwise destruction of the
receptor and / or servos may occur.
-
+
Negative
Positive
Signal
36
!
BAT/PPM
BAT/PPM