Operation Manual
12
DRP 18-4 DEC FF/ PDP 20-4 DEC FF
GB
Noise/vibration information
Levels determined in accordance with EN
60745 are typically:
Vibration emission value a
h
(vector sum for
three directions) and uncertainty K mea-
sured in accordance with EN 60745:
The specified emissions values (vibration,
noise)
– are used to compare machines.
– They are also used for making preliminary
estimates regarding vibration and noise
loads during operation.
– They represent the primary applications of
the power tool.
Increase possible for other applications, with
other insertion tools or if not maintained ad-
equately. Take note of idling and downtimes
of machine!
5 Safety instructions
5.1 General safety instructions
WARNING! Read all safety warn-
ings and all instructions.
Failure to
follow the warnings and instructions may re-
sult in electric shock, fire and/or serious in-
jury.
Save all warnings and instructions for
future reference.
The term "power tool" in the warnings refers
to your mains-operated (corded) power tool
or battery-operated (cordless) power tool.
5.2 Machine-related safety instruc-
tions
–
Wear ear protection when using im-
pact drills.
The effects of noise can cause
hearing loss.
–
Use the additional handles supplied
with the power tool.
Losing control of
the power tool can result in injuries.
–
When performing work where screws
could potentially make contact with
hidden power cables, always hold the
machine by the insulated surfaces on
the handles.
Screws that make contact
with a live cable may also energise metal
Fastening into wood 10 mm
Tool holder in drill spindle 1/4 ’’
Collar 43 mm
Weight 1,7 kg
Safety class /II
Drill / Impact drill DRP 18-4 DEC FF PDP 20-4 DEC FF
DRP 18-4 DEC FF PDP 20-4 DEC FF
Sound pressure level L
PA
86 dB(A) 105 dB(A)
Noise level L
WA
97 dB(A) 116 dB(A)
Uncertainty K 3 dB 3 dB
DRP 18-4 DEC FF PDP 20-4 DEC FF
Drilling into metal a
h
= 5.0 m/s
2
a
h
= 5.0 m/s
2
Impact drilling into concrete - a
h
= 15.0 m/s
2
Fastening a
h
< 2.5 m/s
2
a
h
< 2.5 m/s
2
Uncertainty K = 1,5 m/s
2
K = 1,5 m/s
2
CAUTION
When working with noise
Damage to hearing
X
Always use ear protection.