User`s guide
F: BSC Detailed Command and Response Formats
DC 900-1340I 255
Notes:
1. iICPSize = 528 (Protocol Header size (16) plus two 256-byte translation tables). The two
translation tables follow the Protocol Header in the data area.
2. Zero (0) for Big Endian clients (such as SunOS)
0x4000 for Little Endian clients (such as DEC)
3. DLI return status (See Appendix D)
4. Protocol status (See Appendix D)
5. Translation table (1 or 2); see Appendix C.
6. The usProtSessionID that was returned on the DLI_ICP_CMD_ATTACH command
Table F–10: DLI_PROT_SET_TRANS_TABLE Command and Response
Header Field
Command Value
(Write)
Response Value
(Read)
ICP_header
fill1 0 N/A
fill2 0 N/A
iICPSize See Note 1. N/A
usICPCommand
DLI_ICP_CMD_WRITE DLI_ICP_CMD_WRITE
iICPStatus See Note 2. See Note 3.
usICPParms[0] 0 N/A
usICPParms[1] 0 N/A
usICPParms[2] 0 N/A
Prot_header
usProtCommand
DLI_PROT_SET_TRANS_TABLE DLI_PROT_SET_TRANS_TABLE
iProtModifier N/A See Note 4.
usProtLinkID Link Number Link Number
usProtCircuitID See Note 5. N/A
usProtSessionID See Note 6. See Note 6.
fill3 0 N/A
fill4 0 N/A
fill5 0 N/A