User`s guide

254 DC 900-1340I
BSC Programmers Guide
Notes:
1. 16 plus the size of the data area
2. Zero (0) for Big Endian clients (such as SunOS)
0x4000 for Little Endian clients (such as DEC)
3. DLI return status (See Appendix D)
4. See Table 5–4 on page 116 and Table 5–12 on page 151
5. Protocol status (See Appendix D)
6. The usProtSessionID that was returned on the DLI_ICP_CMD_ATTACH command
Table F 9: BSC 2780/3780 General Commands and Responses
Header Field
Command Value
(Write)
Response Value
(Read)
ICP_header
fill1 0 N/A
fill2 0 N/A
iICPSize See Note 1. See Note 1.
usICPCommand
DLI_ICP_CMD_WRITE DLI_ICP_CMD_WRITE
iICPStatus See Note 2. See Note 3.
usICPParms[0] 0 N/A
usICPParms[1] 0 N/A
usICPParms[2] 0 N/A
Prot_header
usProtCommand See Note 4. See Note 4.
iProtModifier 0 See Note 5.
usProtLinkID Link Number (if
required)
Link Number (if
required)
usProtCircuitID 0 N/A
usProtSessionID See Note 6. See Note 6.
fill3 0 N/A
fill4 0 N/A
fill5 0 N/A