User`s guide
DC 900-1340I 237
Appendix
E
BSC Loopback Test
Program
Note
In this chapter, the DLI API interface applies to both a Freeway
server or an embedded ICP using DLITE. For the embedded ICP,
also refer to the user’s guide for your ICP and operating system (for
example, the ICP2432 User’s Guide for Windows NT (DLITE Inter-
face)).
E.1 Loopback Test Programs
The BSC loopback test programs and test directories are listed in Tab le E– 1 and
Ta ble E– 2, according to operating system (UNIX, VMS, or Windows NT). This section
provides a summary of the steps required to run the loopback test; see the Loopback Test
Procedures document for the details and an example output (this information was pre-
viously in the Freeway Server User’s Guide). The loopback program uses non-blocking
I/O, meaning that the
asyncIO DLI configuration parameter (described in the Freeway
Data Link Interface Reference Guide) must be set to “yes” (the default is “no” for block-
ing I/O).
Table E– 1: BSC 3270 Loopback Test Programs and Directories
Operating System Program BSC 3270 Test Directory
UNIX bsc3270alp.c usr/local/freeway/client/test/bsc3270
VMS
BSC3270ALP.C
SYS$SYSDEVICE:[FREEWAY.CLIENT.TEST.BSC3270]
Windows NT
bsc3270alp.c c:\freeway\client\test\bsc3270