User`s guide
190 DC 900-1340I
BSC Programmer’s Guide
Table 7–1: BSC 3270 ICP Link Parameters and Defaults for Using dlicfg
dlicfg Option Name Default Valid Values
dataRate 9600 75, 110, 135, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 or
56000
clockSource “external” “external” or “internal”
replyTimerLen 3 1–1800
numLeadSync 3 2–8
protocol “BSC3270” “BSC3270”
parity “odd” “none”, “odd” or “even”
charSet “asciilrc8” “asciilrc8” or “ebcdiccrc16”
transBlkSize 512 64–4096
dataTranslation “table1” “disable”, “table1” or “table2”
stationPri “master” “master” or “slave”
convMode “no” “yes” or “no”
retryLimit 3 1–127
pollListDelay 0 0–8192
modemControl “FDX1” “HDX1”, “FDX1”, “HDX2”, or “FDX2”
safeStore ”no” “yes” or “no”
stationID 0 0–32
messageBlocking “dataBlk” “disable”, “dataBlk” or “cmdBlk”
blockChecking “exclFirst” “disable”, “exclFirst” or “inclFirst”
qLimit 0 0–4096
readSession ”no” “yes” or “no”
interpollDelay 0 0–8192
textAddr ”normal” “disable”, “normal”, “autoPrintEm”, or “deviceEm”
dsrDelay 3 1–127
elecInterface “EIA232” “EIA232”, “EIA485”, “EIA530”, “V35”, “unbEIA449” or “EIA562”
msgBlkSize
1
1
The msgBlkSize parameter allows the DLI to configure the ICP message buffer size (equivalent to the Set ICP Mes-
sage Buffer Size command in Section 3.4.1.3 on page 58).
1024 256–8192
writeType
2
2
If you use dlWrite without optional arguments, one of the EOM types is used, depending on the writeType DLI con-
figuration parameter. If writeType is set to “normal,” DLI_PROT_SEND_NORM_DATA_EOM is used; if it is set to “transparent,”
DLI_PROT_SEND_TRANS_DATA_EOM is used.
“normal” “normal” or “transparent”