Installation guide

Chapter 4. Qualification Provisions
This section defines a set of qualification methods and specifies, for each requirement in
Chapter 3, methods or
procedures which can be used to ensure that the requirement has been met.
Table 4-1. Freeway Software Qualification Methods
Section Requirement
Name
Qualification
Method
Notes
Section 3.2.1 DLI/TSI
Server
Test Setup a Freeway with at least 2 serial datalink ports, loaded with
sps_2432b.mem, and with a loopback connector between the 2
serial datalink ports; run the spsalp loopback test.
Section 3.2.2 ICP Host Test Setup a Freeway with at least 2 serial datalink ports, loaded with
sps_2432b.mem, and with a loopback connector between the 2
serial datalink ports; run the spsalp loopback test.
Section 3.2.3 User Interface Test Login to a Freeway and traverse the user menus.
Section 3.8.1 GEN000100 -
Supported
Release
Test Login to a Freeway and execute the command uname -a, and
verify that the results match the version number listed in the
Freeway Software Version Description (SVD) - DC-900-2023
document.
Section 3.8.2 GEN000120 -
Supported
Components
Test Login to a Freeway and execute the command pkg_info, and
verify that the results match the version numbers listed in the
Freeway Software Version Description (SVD) - DC-900-2023
document.
Section 3.8.3 GEN000240 -
Network
Time-Server
Check Login to the Freeway and execute the command ps -ax |grep
"ntpd" to verify that the ntpd daemon is running, and the
command more /tmp/ntp.conf to verify that NTP
configuration is as desired. If the Freeway has had time to
synchronize with other NTP servers, the command ntpq -p will
show which peers it has synchronized with. See the Freeway
Security Features User’s Guide (SFUG) - DC-908-3004
document for details about NTP.
Section 3.8.4 GEN000400 -
Logon Warning
Banner Display
Check Login to the Freeway and execute the command more
/etc/ssh/sshd_config to verify that the "Banner" keyword is
set to "/etc/motd", and the command more /etc/motd to see
the text which is displayed upon login. See the Freeway Security
Features User’s Guide (SFUG) - DC-908-3004 document for
details about the login banner.
Section 3.8.5 GEN000440 -
Logging Login
Attempts
Check Login to the Freeway and execute the command last; grep
"authentication error" /var/log/all.log to verify that
both successful and unsuccessful logins are logged. See the
Freeway Security Features User’s Guide (SFUG) - DC-908-3004
document for details about logging.
25