User guide
154 DC 900-1333Q
Freeway User Guide
5.3.3 ICP Reset Utility
The ICP reset utility is used to reset and download an individual ICP board without
affecting the other ICP boards on the Freeway. The ICP reset utility is located in the
/tmp/boot directory on the Freeway. To use the utility, login to the Freeway as
root/setup and choose “6) Run FreeBSD Shell” from the main menu. Then type the fol-
lowing commands (in bold) and enter the number of the ICP board you wish to reset:
# cd /tmp/boot
# icpreset
ICP board to download (0-15) [0]? 0
ICP Reset Program.
Duration allowed waiting for completion is 1 minute
ICP board number: 0
Session Name: B0L0
Download Completed OK
ICP Reset program completed.
#
5.3.4 ICP Print Utility
The ICP print utility is used to display information from the ICP console port. The ICP
console contains information generated by the protocol software running on the ICP
board. Normally you would never need to access this information. However, if you
encounter a problem with the protocol software, Protogate customer support may ask
you to obtain ICP console information for analysis.
The ICP print utility is located in the /tmp/boot directory on the Freeway. To use the
utility, login to the Freeway as root/setup and choose “6) Run FreeBSD Shell” from the
main menu. Then type the following commands (in bold) along with the number of the
ICP board you wish to access:
# cd /tmp/boot
# icpprint 0
icpprint: Console output from /dev/icp_0:
<@@>VI-200-3300: OS/PROTOGATE 1.3-6 May 20 2010
ICP2432B/e with 4 ports and 32 MB
Free space begins at 0x4010b600