User's Manual

REFLEX RAIL BOARD
SETTINGS AND FUNCTIONS
BLUE - Rate Of Fire (ROF) Values 1 - 45
The ROF setting is used to set the maximum rate of fire of the RAIL™.
The values do not correspond directly to a certain Balls Per Second
(BPS) value. You will need to use the table below to locate your
desired maximum ROF setting.
The factory setting is 20 (
12.5 bps).
Increasing ROF too high will increase probability of ball breakage.
If this occurs decrease ROF setting.
YELLOW - Firing Mode Values 1 - 4 (default 1)
This setting changes the firing mode of the REFLEX RAIL™. Default is
semiautomatic. In the semiautomatic mode, one trigger pull shoots
out one paintball. The PSP mode and the Millennium modes follow
the rules of the paintball tournament series.
Value 1 - Semi-automatic Mode
Value 2 - Millennium Mode
Value 3 - PSP Mode
Value 4 - Full auto with first shot safety feature
W W W . P R O T O P A I N T B A L L . C O MW W W . P R O T O P A I N T B A L L . C O M
10 11
1 9.80 BPS
2 9.90 BPS
3 10.0 BPS
4 10.10 BPS
5 10.20 BPS
6 10.30 BPS
7 10.41 BPS
8 10.52 BPS
9 10.63 BPS
10 10.75 BPS
11 10.86 BPS
12 10.98 BPS
13 11.11 BPS
14 11.62 BPS
15 11.76 BPS
16 11.90 BPS
17 12.04 BPS
18 12.19 BPS
19 12.34 BPS
20
12.50 BPS
21 12.65 BPS
22 12.82 BPS
23 12.98 BPS
24 13.15 BPS
25 13.33 BPS
26 13.51 BPS
27 13.69 BPS
28 13.88 BPS
29 14.08 BPS
30 14.28 BPS
31 14.49 BPS
32 14.70 BPS
33 14.92 BPS
34 15.15 BPS
35 15.38 BPS
36 15.62 BPS
37 15.87 BPS
38 16.12 BPS
39 16.39 BPS
4016.66 BPS
41 20.00BPS
42 20.22 BPS
43 25.0 BPS
44 28.57 BPS
45 33.33 BPS
REFLEX RAIL BOARD
SETTINGS AND FUNCTIONS
GREEN - Trigger Sensitivity Values 1 - 20 (factory default 5)
Trigger sensitivity is the amount of time that the trigger has to be
released before the next trigger pull is allowed. In some situations
with too low of a value, the REFLEX RAIL™ can register more trigger
than what was actually pulled. This can cause the REFLEX RAIL™ to
auto, even in semi-automatic mode. To fix this, adjust the trigger
sensitivity setting higher.
RED - Dwell Values 1 - 30 (factory default 18)
Dwell is the amount of time that the solenoid will be activated.
Follow these steps for the best way to set your dwell:
• Remove loader and any paintballs from the RAIL™ marker.
• With the dwell set at 10, start increasing the value until the marker
begins to fire.
• When you reach the setting where the marker begins to fire, get
some paint and a loader and go to a chronograph.
• Increase the dwell until you see no increase in the velocity.
This is the optimal dwell setting to be used.
NOTE: You cannot turn your marker off with the power button
when the marker is in configuration mode. You must first set DIP
switch 2 to the OFF position.
2011-Reflex-RAIL-Manual.qx_2011-Reflex-RAIL-Manual 11/22/10 12:40 PM Page 13