User manual
CONFIDENTIAL Protium Technologies, Inc. 4050-9901
Rev No: 05
5 GHz RF Modem 31-Jan-2007 63 of 84
This document and information contained herein is subject to the restrictions set forth on the title page
.
"Hardware MAC address for payload ethernet port"
::= { protiumTechPersistantConfig 13 }
--
-- testModes objects
--
panelLedTM OBJECT-TYPE
SYNTAX INTEGER { normal(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test all panel LEDs. All Leds are forced on."
::= { protiumTechTestModes 1 }
alarmRelayTM OBJECT-TYPE
SYNTAX INTEGER { normal(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test all alarm relays. Alarm relay states are inverted."
::= { protiumTechTestModes 2 }
coolingFansTM OBJECT-TYPE
SYNTAX INTEGER { normal(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test both cooling fans. Both fans are forced on."
::= { protiumTechTestModes 3 }
loopbackTM OBJECT-TYPE
SYNTAX INTEGER { off(0), local(1), remote(2), locrem(3), traffic(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Local loopback loops the interface receivers to the
drivers. No modem functions are exercised.
Remote loopback loops the received bit stream back to
the transmitter. Symbol decoding and encoding are
exercised; Interleaving and error correction are not.
Traffic loopback loops the local interface input to
the local output. Serialization, deserialization,
framing, interleaving, and error correction are all
exercised; symbol encoding and decoding are not."
::= { protiumTechTestModes 4 }
rfLoopbackTM OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Attempt RF loopback. Sets the receiver to the same
frequency as the transmitter and set the transmitter
to minimum power (maximum attenuation). Leakage may
allow the radio to receive its own signal. Maybe."
::= { protiumTechTestModes 5 }
modulationTM OBJECT-TYPE
SYNTAX INTEGER { normal(0), off(1) }
MAX-ACCESS read-write