::= { errorHistogram 4 }
blocksWith5Errs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of blocks processed by the R-S decoder that
had 5 corrected error bytes."
::= { errorHistogram 5 }
blocksWith6Errs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of blocks processed by the R-S decoder that
had 6 corrected error bytes."
::= { errorHistogram 6 }
--
-- interfacesInfo objects
--
dataSharerExists OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether a data sharer (port B) exists."
::= { interfacesInfo 1 }
--
-- interfacesConfig objects
--
baudrate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Asynchronous: 300 | 600 | 1200 | 2400 | 4800 | 9600 | 14400 | 19200
Synchronous: 64 | 128"
::= { interfacesConfig 1 }
serialMode OBJECT-TYPE
SYNTAX INTEGER { synchronous(0), asynchronous(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port protocol. This is read-only because it is set
implicitly by the baudrate"
::= { interfacesConfig 2 }
interfaceType OBJECT-TYPE
SYNTAX INTEGER { eia530(0), eia232(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface driver type"