SYNTAX Integer32
UNITS "degrees C"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature alarm threshold of the modem module in degrees C."
::= { modemConfig 3 }
frameLocked OBJECT-TYPE
SYNTAX INTEGER { unlocked(0), locked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive frame lock state"
::= { modemStatus 1 }
modemTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the modem board in degrees C."
::= { modemStatus 3 }
peakModemTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peak temperature of the modem board in degrees C."
::= { modemStatus 4 }
totalKBytes OBJECT-TYPE
SYNTAX Counter32
UNITS "KBytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of kilobytes processed by the R-S decoder
(using the computer science definition of 1024 bytes
per kilobyte)."
::= { modemStats 1 }
correctedBytes OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes corrected by the R-S decoder."
::= { modemStats 2 }
totalBlocks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of blocks processed by the R-S decoder."
::= { modemStats 3 }