5 GHz RF Modem 31-Jan-2007 54 of 84
This document and information contained herein is subject to the restrictions set forth on the title page
.
::= { radioConfig 5 }
radioRslAlarmThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "cBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low received signal alarm threshold in cBm (centibels referred to 1 mW)."
::= { radioConfig 6 }
radioTempAlarmThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees C"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature alarm threshold of the radio module in degrees C."
::= { radioConfig 7 }
powerAmpTempAlarmThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees C"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature alarm threshold of the power amplifier in degrees C."
::= { radioConfig 8 }
muteState OBJECT-TYPE
SYNTAX INTEGER { unmuted(0), mutedByOper(1), mutedByConfigErr(2),
mutedBySynthUnlocked(3), mutedForReconfig(4),
mutedByRTS(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual mute state. The value is 1 if the radio is muted by operator
command; the value is 2 if the operator has attempted to unmute the
radio but it is prevented by mis-configuration (probably illegal TX
frequency); the value is 3 if the frequency is okay but the synthesizer
is out of lock; the value is 4 if the radio is temporarily muted while
it is being reconfigured; the value is 5 if configured for multi-point
and the request-to-send (RTS) line on the serial port is negated."
::= { radioStatus 1 }
txSynthLocked OBJECT-TYPE
SYNTAX INTEGER { unlocked(0), locked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit synthesizer lock state"
::= { radioStatus 2 }
rxSynthLocked OBJECT-TYPE
SYNTAX INTEGER { unlocked(0), locked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive synthesizer lock state"
::= { radioStatus 3 }