User manual
CONFIDENTIAL Protium Technologies, Inc. 4050-9901
Rev No: 05
5 GHz RF Modem 31-Jan-2007 33 of 84
This document and information contained herein is subject to the restrictions set forth on the title page
.
Total blocks: 0 The total number of block processed by the error
correction logic. A block contains up to 200 actual
data bytes.
Errored blocks: 0 The number of blocks that had a detected error.
Uncorrected blks: 0 The number of blocks that had uncorrectable errors.
Corrected blocks: 0 The number of blocks that had corrected errors.
If there are any corrected blocks, a table is printed indicating how many blocks
had one error, how many had two errors, and so forth.
4.2.43 syslog System Logging
Usage: syslog [<none|info|debug>]
Authorization: Operator RO; Administrator RW
With no argument, display the current system logging level. Otherwise, set the
specified system logging level.
Multiple arguments may be specified, in which case each argument is applied in
the order given. For example,
syslog none debug
will clear all optional logging and then enable logging of debug messages.
The modem sends system messages to a syslog host if one is specified. When a
host is specified, the messages are sent using the “syslog” UDP protocol to port
514. Syslog messages are categorized in to multiple levels based on the severity
of the condition and the importance of the message. The “info” and “debug” log
level messages are optional and are disabled by default. All other messages levels
are considered error messages and are always enabled.
The “info” and/or “debug” log levels may be useful for debugging is certain
limited circumstances but should otherwise be off.
4.2.44 temp Temperature
Usage: temp
Authorization: Operator RO; Administrator RO
Display the temperature of the modem, the RF module, and the power amplifier.
4.2.45 tempthr Temperature Alarm Thresholds
Usage: tempthr [<rf|pa|modem>] [nn]
Authorization: Operator RO; Administrator RW
If the temperature argument (nn) is absent, display the current temperature alarm
thresholds. Otherwise sets the temperature alarm threshold to nn°C.