User manual

CONFIDENTIAL Protium Technologies, Inc. 4050-9901
Rev No: 05
5 GHz RF Modem 31-Jan-2007 30 of 84
This document and information contained herein is subject to the restrictions set forth on the title page
.
4.2.33 newaccount Create Login Account
Usage: newaccount name type
Authorization: Operator N/A; Administrator RW
Create the named login account. Account names must begin with a letter, must be
no more than 16 characters, and must be unique. Account names are case
sensitive. Only the characters A-Z, a-z, 0-9, dash, and underbar are allowed.
4.2.34 passwd Set Passwords
Usage: passwd [account]
Authorization: see below
Change login password. If no account name is specified, change the password for
the currently logged in account. If an account is specified, change the password
for that account. Only administrators can change the password for another
account. Operators can only change their own password.
The new password will be solicited twice and the two entries are required to
match in order to catch typing errors.
Passwords are case sensitive. New passwords are subjected to a series of tests
designed to reject passwords that are too simple and/or easy to guess. Passwords
must have at least characters. Those with two or more numerals, a mixture of
uppercase and lowercase letters, and some punctuation are more likely to be
accepted.
4.2.35 rsl Received Signal Level
Usage: rsl
Authorization: Operator RO; Administrator RO
Display the current received signal level.. This display is updated continuously
until the return/enter key is pressed.
4.2.36 rslthr RSL Alarm Threshold
Usage: rslthr [-nnn.n]
Authorization: Operator RO; Administrator RW
Display or set the received signal level alarm threshold.
If the RSL falls below the specified value, a low received signal alarm is
declared.
Without an argument, display the current RSL threshold.
With a numeric argument, sets the RSL alarm threshold to -nnn.n dBm.
4.2.37 rtsenable Data Sharer RTS Enable or Disable
Usage: rtsenable [<both|a|b|none>]