Maintenance
FUEL FILTER:
The fuel filter should be cleaned at least twice per
heating season. Clean the filter by rinsing it in clean
K-1 Kerosene. Contaminated fuel could make cleaning
the fuel filter necessary immediately.
NOTE: To remove the lter from models turn lter 90º
counter-clockwise. See Figure 6.
SPARK PLUG:
Clean and re-gap every 600 hours of operation, or
replace as needed. After removing the spark plug, clean
the terminals with a wire brush. Re-gap the terminals to
0.140” (3.5mm) See Figure 7.
PHOTOCELL:
The photocell should be cleaned using a cotton swab
dipped in alcohol or water at least once per heating
season, or more depending on conditions. See Figure
8.
NOZZLES:
Nozzles should be cleaned or replaced at least once
per heating season. Contaminated fuel could make
this necessary immediately. To clean dirt from nozzle,
blow compressed air through nozzle front. It may be
necessary to soak the nozzle in K-1 kerosene to loosen
any dirt particles. See Figure 9.
Figure 7
Ignitor Wire
Spark Plug
Gap (3.5 mm)
Burner Head
X
X
Photocell
Photocell lens
Photocell Wire
Figure 8
Figure 9
Nozzle
Nozzle Face
Burner Head
Dispenser
Figure 6
Fuel Filter
Fuel Line
Fuel Tank