Use and Care Manual

© 2019 Pinnacle Climate Technologies, Inc. Silent Drive Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
8
®
MAINTENANCE
Long Term Storage:
1. Drain fuel through the drain bolt in the bottom of
the fuel tank.
2. To remove the drain bolt, unscrew counterclockise
(see Figure 4). A 6 mm hex key (not provided) is
required to unscrew the drain bolt.
3. Using a small amount of kerosene, rinse and swirl
the kerosene inside of the fuel tank, empty the
tank fully.
4. To replace the drain bolt; insert the drain head
fully into the drain hole and screw clockwise.
IMPORTANT: Never store leftover kerosene between seasons,
using old fuel can damage heater.
Service:
DO NOT TAMPER WITH THE UNIT. HAVE A
COMPETENT SERVICEMAN MAKE ANY NECESSARY
ADJUSTMENT OR REPAIRS.
Use only original equipment parts. The use of alternate
or third party components can cause unsafe operating
conditions and will void your warranty.
We suggest following a maintenance schedule as follows:
FUEL / FUEL TANK:
Flush tank every 200 hours of operation or as needed.
DO NOT flush with water, use fresh K-1 kerosene only.
FAN BLADES:
Blades should be cleaned at least once per heating
season, depending on conditions. Remove all
accumulated dust and dirt with a damp cloth, taking
care not to bend any of the fan blades. Be sure the
blades are dry before re-starting the heater. For fan
assembly removal, see Figure 5.
Drain Bolt
Figure 4
TIP: To order OEM parts call (800) 641-6996
Figure 5
Fan Blade
Motor Shaft
Set Screw
Never service heater
while it is plugged
in or hot!
WARNING
Motor
Sirroco Fan