NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
7
®
OPERATION (CONT.)
Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved fuel
until needle on fuel gauge points to “F”.
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong (grounded)
power source. You must use a three prong
(grounded) extension cord that is at least 6 feet
long and is a minimum of 14 AWG rating.
4. Press the power button to power on the heater
(see Figure 3).
5. Select desired temperature using temperature +/-
buttons.
6. The heater will ignite once the temperature setting
is higher than the ambient temperature in the
space.
Stopping / Restarting Heater:
- To stop the heater, move the power switch to the
“Off” position and unplug the power cord.
- To restart the heater; wait 10 seconds and follow
ignition steps.
Adjusting the Pump Pressure:
- Remove the right side cover (4 screws). Behind the
panel, the pump will have a Phillips screw. There
is a small “P” next to the pump adjustment screw.
Turn screw in quarter turn increments.
- Clockwise increases the pressure.
- Counterclockwise decreases pressure.
TIP: If the heater does not ignite; press power
button to power off the heater, check steps 1-3
above and press power button to power ON the
heater.
TIP: If the heater does not ignite, the thermostat
may be set too low. Increase the temperature to a
higher setting until the heater ignites.