PTK-8519 625 DUO Touch AC Battery Charger Manual
07
WARNING AND SAFETY NOTES
Standard Battery Parameters
3.7V/cell
3.7V/cell
4.2V/cell
3.8V/cell
≦1C
3.6V/cell
4.1V/cell
≦1C
3.3V/cell
3.6V/cell
3.3V/cell
≦4C
3.0-3.3V/cell 2.9-3.2V/cell
2.6-2.9V/cell
1.2V/cell
1.5V/cell
n/a
1C-2C
1.2V/cell
1.5V/cell
n/a
1C-2C
2.0V/cell
2.46V/cell
n/a
≦0.4C
0.1-1.1V/cell 0.1-1.1V/cell
1.8V/cell
3.7V/cell
4.35V/cell
3.85V/cell
≦1C
3.1-3.4V/cell
Nominal
Voltage
Max Charge
Voltage
Storage
Voltage
Allowable
Fast Charge
Min.Discharge
Voltage
LiPo
LiIon LiFe
NiCd MiMH
PbLiHV
※
Be very careful to choose the correct voltage for different types of
battery otherwise you may cause damage to the batteries. Incorrect
settings could cause the cells to fire or Explode.
Never attempt to charge or discharge the following types of
batteries
● A battery pack, which consists of different types of cells (including
different manufacturers).
● A battery that is already fully charged or just slightly discharged.
● Non-rechargeable batteries (Explosion hazard).
● A faulty or damaged battery.
● A battery fitted with an integral charge circuit or a protection circuit.
● Batteries installed in a device or which are electrically linked to other
components.
● Batteries that are not expressly stated by the manufacturer to be
suitable for the currents the charger delivers during the charge
process.
Please keep in mind the following points before charging
● Did you select the appropriate program suitable for the type of
battery you are charging?
● Did you set up adequate current for charging or discharging?
● Have you checked the battery voltage? Lithium battery packs can be
wired in parallel and in series, i.e. a 2 cell pack can be 3.7V (in parallel)
or 7.4V (in series).
● Have you checked that all connections are firm and secure? Make
sure there are no intermittent contacts at any point in the circuit.