PTK-8519 625 DUO Touch AC Battery Charger Manual

23
SYSTEM SETTING
Go to next screen
Set precharge time: OFF/1-10min.
Set temperature unit /
Set cut-off temperature, ranges
from 20 to 80(68-176)
Set input voltage, ranges from
11.0V to 18.0V
Set Input current limited value,
1.0A-55.0A/AUTO
Notice: Please set the parameters in Setup menu when charger is powered
on for the first time.
This charger can recognize battery cell count automatically. It has a
pre-charge function which can reactivate the slightly over discharged cell.
Users can set the pre-charge time (normally 2 minutes) in the menu.
The more battery capacity, the more time is needed.
Attention: In the normal charge mode, always turn off the precharge
program. DO NOT use this function unless you know the battery status very
well. Stop the process immediately when battery voltage increase quite few,
or it may cause danger!!!