Specifications
70 Module 124: Protege GX Hardware Overview | The Protege PCB Range
Protege Ethernet 2 Reader Expander (PRT-RDE2)
The RDE2 has all of the intelligence of the RDI2, but with an onboard Ethernet interface. It can be plugged
virtually anywhere on the network allowing the use of existing network infrastructure. The RS-485 ports can
then be used to extend the network in four directions for elevator control or 3rd party system integrations.
Technical Specifications:
Operating Current: 119mA (207mA max all relays activated)
AC Input: 16VAC, 40VA
DC Output (Aux): 1.2A Fused & Monitored
PSU: Local monitored PSU with battery backup
Doors: 2 doors, up to 4 readers in multiplex mode
Inputs: 8 4 state, EOL configurable. 1 module tamper
Outputs: 2 12VDC monitored lock outputs (1A continuous, 1.2A
max) or 2x Form C relays outputs for lock control (no lock
monitoring), 6 open collector outputs (50mA)
Offline Operation: 2000 users, schedules, 2000 events
Comms: 2 Galvanic isolated RS-485 ports, 1 10/100 Ethernet port
Maximum Number per Enclosure
Medium Large Fatboy Jumbo
- 1 2 4
Requires 1 16VAC, 40VA 16 Transformer (TFR-40-16)