Specifications
Level One: Protege GX Installer Study Guide | August 2013 49
8 Onboard Inputs
Use for access control, detection devices such as PIRs, or a mixture of both
Most common EOL combinations supported (no need to change resistors when upgrading)
Monitor more inputs by adding input expanders (500+ inputs supported)
7 Onboard Outputs
One 12VDC 1.1A Bell output
Two high current (7A) relays for control of locks, lights, etc
Four low current (50mA) outputs for LED / buzzer control
Control more outputs by adding output expanders (500+ outputs supported)
PRT-CTRL-DIN: Technical Specifications
Technical Specifications
Operating Voltage 12V DC +- 10%
Operating Current 120mA (Typical)
DC Output (Aux) 0.7A (Typical) Electronic Shutdown at 1.1A
Bell DC Output (Continuous) 8 Ohm 30W Siren or 1.1A (Typical)
Bell DC Output (Inrush) 1500mA
Communication 1 10/100Mbps Ethernet Communication Link
1 RS-485 Communication Interface Port
Readers (Standard) 2 Wiegand or clock data readers providing one Entry/Exit Door or two
Entry/Exit only Doors
Readers (Multiplex) 4 Wiegand Readers (connected in Multiplex Reader mode) providing any
combination of Entry or Exit for two Doors
Inputs (System Inputs) 8 High Security Monitored Inputs
Outputs 4 50mA (Max) Open Collector Output for reader LED and beeper or
general functions
Relay Outputs 2 FORM C Relays - 7A max