6. Use the Find tool to locate the PIR inputs
7. Set the Input Type to Instant
8. Use the Find tool to locate the Reed inputs
9. Set the Input Type to Instant
10. Use the Find tool to locate the Showroom inputs
11. Select the Showroom PIR and Showroom Door Reed, then click the Areas and Input Types tab.
12. Set the First Assigned Area to Showroom
13. Use the Find tool again to locate inputs with the word Warehouse
14. Select the first five inputs (the 4 Warehouse PIRs and the Warehouse Roller Reed) and set the First
Assigned Area to Warehouse
15. Select the Showroom to Warehouse Door Reed input
16. Set the First Assigned Area to Showroom
17. Set the Second Assigned Area to Warehouse and the Input Type to Instant
Task 8: Creating a New Door Type
1. Navigate to Programming | Door Types:
2. Add a new door type called Showroom
3. Set the Operating Schedule to Showroom Armed
4. Set the Secondary Type to Card
5. Set the Entry Reading Mode to Card and PIN